Fotinho REE - Additional Alluvial Targets from Assay Results
Released
Released
Announcement PDF
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
ASX ANNOUNCEMENT
1 July 2026
Auger Assay Results >3% THM deliver additional Alluvial Targets at
Fotinho REE Project
High THM analytical results were received from 57 target generation auger drillholes in alluvial
targets within Fotinho (11000):
o 26 of the 57 holes returned results >3% THM over the entire drilling depth (refer
Table 2, red highlights).
o Highest grade of 7.69% THM over 1.00m depth (Table 2).
o The results also show that some of the auger holes carry high grades to over 3.0m
depth, such as FHA26044 which assayed 4.76% THM over 3 metres (Table 2).
o The weighted grade average for all 57 holes, using no cut off, is an average of 2.95%
THM over an average thickness of 1.38m.
o Many of the holes stopped in the water table, or where the auger drilling could not
penetrate coarser alluvial material.
• Results from these 57 holes are in addition to the initial 32 holes at Fotinho, which in turn
build on the assay results from 46 auger holes at 5 alluvial targets at the adjacent Adriano
project. The results confirm significant alluvial heavy mineral potential across the Adriano-
Fotinho 396.42 sq km area (refer Figures 1 & 2).
• The results from Fotinho are seen in conjunction with the mineralogy results previously
reported from a composite HMC sample derived from 4 alluvial targets within Adriano
showing high Valuable Heavy Mineral (VHM) content:
▪ 1.9% Monazite;
▪ 2.3% Rutile;
▪ 1.90% Zircon;
▪ 1.8% Leucoxene; and
▪ 24.4% Ilmenite.
▪ 32.2% Total VHM of the HMC.
• These highly encouraging results from the alluvial target generation auger drilling at both
Adriano and Fotinho, will be followed up by grid-based auger drilling to rapidly assess the
size of the potential mineralised footprint.
MRG Metals Limited (ASX: MRQ) (“MRG” or “the Company”) is pleased to announce the laboratory
analytical results (refer Table 2) for 57 auger drillholes (refer Table 1 for coordinates), drilled in an
alluvial footprint at the Fotinho Rare Earth Project in Mozambique. The analytical results from the
57 auger drillholes (refer Table 2, Figure 1), in combination with the initial analytical THM results
from 32 auger holes in Fotinho (refer ASX Announcement 11 June 2026), and the high laboratory
analytical results received for the initial 46 auger holes drilled at 5 alluvial target areas in the adjacent
Adriano Rare Earth Project (refer ASX Announcements 9 October 2025; 16 October 2025; 23 October
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
2025; 27 October 2025 and 4 March 2026)(refer Figure 2), confirms an alluvial Heavy Mineral (HM)
target over this combined Adriano-Fotinho 396.42 sq km area.
Initial mineralogical investigations and chemical analyses from a Heavy Mineral Concentrate (HMC)
sample derived from Adriano confirmed the TREO potential of the Adriano-Fotinho area (refer ASX
Announcements 13 May 2026). This initial mineralogy study showed the high Valuable Heavy
Mineral (VHM) content of an HMC sample to be as follows:
• 1.9% Monazite;
• 2.3% Rutile;
• 1.90% Zircon;
• 1.8% Leucoxene; and
• 24.4% Ilmenite.
• A 32.2% Total VHM of the HMC.
Grid drilling programs to define the width, strike and depth potential of alluvial HM deposits based
on the generated targets will now commence. Mineralogical investigations of HMC from Fotinho, as
well as more detailed lithologically based mineralogical investigations from Adriano, will be taking
place.
Table 1: Coordinates of all 57 hand auger holes drilled within Fotinho 11000, as well as outcrop points
at planned drilling positions (handheld GPS data, UTM)
HOLE_ID UTM_N_WGS84 UTM_E_WGS84 ELEVATION_M DIP AZIMUTH
FHA26034 8046475 801814 107 -90 360
FHA26035 8053135 810688 107 -90 360
FHA26036 8052989 813310 91 -90 360
FHA26037 8054188 814052 94 -90 360
**FRC26038 8055868 814183 106 NA NA
FHA26039 8055851 814203 106 -90 360
FHA26040 8056809 814535 111 -90 360
**FRC26041 8056801 814525 110 NA NA
**FRC26042 8056793 814816 99 NA NA
FHA26043 8058411 814757 100 -90 360
FHA26044 8058380 815065 104 -90 360
FHA26045 8059277 814489 116 -90 360
FHA26046 8059864 813654 116 -90 360
FHA26047 8060831 813031 113 -90 360
FHA26048 8061434 816102 153 -90 360
FHA26049 8060730 815427 136 -90 360
FHA26050 8061176 815056 132 -90 360
FHA26051 8060646 814626 124 -90 360
FHA26052 8059998 814937 120 -90 360
FHA26053 8049766 801582 117 -90 360
FHA26054 8052103 807369 120 -90 360
FHA26055 8051568 806968 134 -90 360
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
FHA26056 8051065 807696 119 -90 360
**FRC26057 8051160 808088 120 NA NA
FHA26058 8050978 808560 111 -90 360
FHA26059 8051289 809156 96 -90 360
FHA26060 8049061 801256 127 -90 360
FHA26061 8048727 801464 128 -90 360
FHA26062 8048129 800805 110 -90 360
FHA26063 8048077 802678 167 -90 360
FHA26064 8047379 802381 123 -90 360
FHA26065 8046941 802612 120 -90 360
FHA26066 8045274 802703 97 -90 360
**FRC26067 8045264 802721 94 NA NA
FHA26068 8045009 801649 101 -90 360
FHA26069 8046815 803772 125 -90 360
**FRC26070 8046820 803789 128 NA NA
FHA26071 8051835 813568 96 -90 360
FHA26072 8050734 810047 109 -90 360
**FSSD26073 8050738 810038 108 NA NA
**FRC26074 8050734 810069 108 NA NA
**FSSD26075 8050497 809848 107 NA NA
FHA26076 8050128 809270 106 -90 360
**FSSD26077 8050132 809266 106 NA NA
FHA26078 8049989 805798 126 -90 360
**FSD26079 8050008 805786 127 NA NA
FHA26080 8049114 806171 126 -90 360
FHA26081 8053160 807633 112 -90 360
FHA26082 8053514 807466 110 -90 360
FHA26083 8053838 807540 100 -90 360
FHA26084 8054190 806515 118 -90 360
**FRC26085 8054836 805576 112 NA NA
FHA26086 8054977 805677 102 -90 360
FHA26087 8053609 805495 122 -90 360
**FRC26088 8053641 805477 123 NA NA
**FRC26089 8053644 804366 130 NA NA
FHA26090 8054150 804389 134 -90 360
FHA26091 8052501 804124 140 -90 360
FHA26092 8054421 803266 143 -90 360
FHA26093 8054559 802769 149 -90 360
**FRC26094 8054545 802992 148 NA NA
FHA26095 8053380 803249 138 -90 360
FHA26096 8053572 806337 125 -90 360
FHA26097 8053187 804951 127 -90 360
FHA26098 8053166 805753 111 -90 360
FHA26099 8052547 807065 115 -90 360
**FRC26100 8052546 807053 119 NA NA
**FRC26101 8052546 807045 119 NA NA
FHA26102 8052355 805871 130 -90 360
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
FHA26103 8052051 804016 146 -90 360
FHA26104 8052119 805306 133 -90 360
FHA26105 8051595 805334 149 -90 360
FHA26106 8051280 805572 148 -90 360
FHA26107 8050955 806004 150 -90 360
** Outcrop at surface, thus no auger drilling at these points
Table 2: Analytical results from MAK Analytical of all 57 hand auger holes drilled within Fotinho
11000. Holes with >3.0% THM highlighted in red.
Hole ID Sample ID
OVERSIZE
(%)
SILT
(%)
THM
(%)
THM (%)
/ HOLE
HOLE
INTERVAL
FROM TO INTERVAL
FHA26034
FHA2603401 0.0 1.0 1.00 11.69 8.70 3.12
2.97 1.5
FHA2603402 1.0 1.5 0.50 44.50 4.94 2.69
FHA26035
FHA2603501 0.0 1.0 1.00 13.08 40.60 0.81
0.67 1.5
FHA2603502 1.0 1.5 0.50 14.81 32.79 0.39
FHA26036 FHA2603601 0.0 1.0 1.00 14.23 34.22 3.56 3.56 1.0
FHA26037 FHA2603701 0.0 1.0 1.00 3.45 31.57 3.98 3.98 1.0
FHA26039 FHA2603901 0.0 0.8 0.80 15.71 26.50 3.61 3.61 0.8
FHA26040 FHA2604001 0.0 1.0 1.00 8.16 16.16 3.27 3.27 1.0
FHA26043
FHA2604301 0.0 1.0 1.00 13.55 11.93 4.03
4.24 1.5
FHA2604302 1.0 1.5 0.50 6.68 5.81 4.66
FHA26044
FHA2604401 0.0 1.0 1.00 0.42 20.53 5.20
4.76 3.0
FHA2604402 1.0 2.0 1.00 1.09 31.59 4.26
FHA2604403 2.0 3.0 1.00 1.30 25.82 4.80
FHA26045
FHA2604501 0.0 1.0 1.00 3.01 28.34 3.58
2.75 2.0
FHA2604502 1.0 2.0 1.00 25.20 28.20 1.92
FHA26046
FHA2604601 0.0 1.0 1.00 45.17 10.51 2.12
4.46 3.0
FHA2604602 1.0 2.0 1.00 17.31 12.65 4.75
FHA2604603 2.0 3.0 1.00 4.13 16.92 6.51
FHA26047 FHA2604701 0.0 1.0 1.00 4.16 28.28 4.24 4.24 1.0
FHA26048
FHA2604801 0.0 1.0 1.00 19.44 47.09 0.55
0.73 2.5
FHA2604802 1.0 2.0 1.00 7.12 53.17 0.35
FHA2604803 2.0 2.5 0.50 5.63 30.34 1.87
FHA26049
FHA2604901 0.0 1.0 1.00 18.36 19.97 2.06
1.90 1.5
FHA2604902 1.0 1.5 0.50 15.54 30.38 1.58
FHA26050 FHA2605001 0.0 1.0 1.00 21.40 29.48 0.73 0.73 1.0
FHA26051 FHA2605101 0.0 1.0 1.00 15.52 19.25 2.59 2.59 1.0
FHA26052 FHA2605201 0.0 1.0 1.00 11.81 43.46 1.03 1.03 1.0
FHA26053
FHA2605301 0.0 1.0 1.00 0.75 14.26 2.29
2.30 1.5
FHA2605302 1.0 1.5 0.50 9.50 10.85 2.31
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
FHA26054 FHA2605401 0.0 1.0 1.00 2.14 65.86 0.84 0.84 1.0
FHA26055 FHA2605501 0.0 1.0 1.00 2.36 48.13 1.97 1.97 1.0
FHA26056
FHA2605601 0.0 1.0 1.00 29.65 17.37 2.70
2.90 1.3
FHA2605602 1.0 1.3 0.30 18.25 17.23 3.57
FHA26058 FHA2605801 0.0 1.0 1.00 33.84 9.42 7.69 7.69 1.0
FHA26059 FHA2605901 0.0 1.0 1.00 16.71 25.08 3.17 3.17 1.0
FHA26060
FHA2606001 0.0 1.0 1.00 4.09 12.38 2.43
2.10 2.0
FHA2606002 1.0 2.0 1.00 5.06 21.01 1.76
FHA26061 FHA2606101 0.0 1.0 1.00 2.32 10.68 2.58 2.58 1.0
FHA26062
FHA2606201 0.0 1.0 1.00 3.22 9.46 2.72
2.72 2.0
FHA2606202 1.0 2.0 1.00 3.79 4.15 2.71
FHA26063
FHA2606301 0.0 1.0 1.00 0.70 17.02 2.17
2.48 1.5
FHA2606302 1.0 1.5 0.50 1.34 14.13 3.09
FHA26064
FHA2606401 0.0 1.0 1.00 1.01 11.73 2.90
2.49 2.0
FHA2606402 1.0 2.0 1.00 3.86 13.21 2.08
FHA26065 FHA2606501 0.0 1.0 1.00 5.07 14.79 4.43 4.43 1.0
FHA26066 FHA2606601 0.0 1.0 1.00 20.34 12.96 2.70 2.70 1.0
FHA26068 FHA2606801 0.0 0.8 0.80 19.34 10.75 3.25 3.25 0.8
FHA26069 FHA2606901 0.0 1.0 1.00 4.53 17.66 4.41 4.41 1.0
FHA26071
FHA2607101 0.0 1.0 1.00 8.21 29.10 1.17
1.14 1.5
FHA2607102 1.0 1.5 0.50 22.32 18.23 1.09
FHA26072 FHA2607201 0.0 1.0 1.00 8.54 10.01 5.59 5.59 1.0
FHA26076 FHA2607601 0.0 1.0 1.00 8.72 11.25 5.24 5.24 1.0
FHA26078 FHA2607801 0.0 1.0 1.00 9.61 29.60 4.44 4.44 1.0
FHA26080
FHA2608001 0.0 1.0 1.00 0.85 34.79 3.95
2.64 3.0
FHA2608002 0.0 2.0 2.00 6.69 44.33 1.98
FHA26081 FHA2608101 0.0 1.0 1.00 21.80 10.21 2.06 2.06 1.0
FHA26082 FHA2608201 0.0 1.0 1.00 32.73 8.80 2.34 2.34 1.0
FHA26083
FHA2608301 0.0 1.0 1.00 0.59 19.12 4.55
4.04 2.0
FHA2608302 1.0 2.0 1.00 6.89 21.14 3.53
FHA26084
FHA2608401 0.0 1.0 1.00 3.80 50.64 1.21
1.73 3.0
FHA2608402 1.0 2.0 1.00 5.52 48.33 1.59
FHA2608403 2.0 3.0 1.00 3.26 43.47 2.40
FHA26086
FHA2608601 0.0 1.0 1.00 1.48 11.75 4.93
5.45 1.5
FHA2608602 1.0 1.5 0.50 12.49 14.26 6.50
FHA26087 FHA2608701 0.0 1.0 1.00 19.20 14.99 4.12 4.12 1.0
FHA26090 FHA2609001 0.0 1.0 1.00 12.50 47.41 1.46 1.46 1.0
FHA26091 FHA2609101 0.0 0.5 0.50 7.51 47.19 3.30 3.30 0.5
FHA26092 FHA2609201 0.0 1.0 1.00 12.47 15.13 7.15 7.15 1.0
FHA26093 FHA2609301 0.0 1.0 1.00 15.06 26.56 2.88 2.88 1.0
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
FHA26095 FHA2609501 0.0 1.0 1.00 4.47 49.53 3.17 3.17 1.0
FHA26096
FHA2609601 0.0 1.0 1.00 4.16 17.16 3.32
3.19 1.5
FHA2609602 1.0 1.5 0.50 19.78 13.26 2.94
FHA26097
FHA2609701 0.0 1.0 1.00 10.18 40.34 2.09
2.22 2.0
FHA2609702 1.0 2.0 1.00 11.49 32.19 2.35
FHA26098 FHA2609801 0.0 0.5 0.50 16.40 16.18 3.92 3.92 0.5
FHA26099 FHA2609901 0.0 1.0 1.00 15.59 29.52 1.88 1.88 1.0
FHA26102 FHA2610201 0.0 1.0 1.00 12.37 41.98 2.08 2.08 1.0
FHA26103
FHA2610301 0.0 1.0 1.00 7.13 72.68 4.29
3.06 2.0
FHA2610302 1.0 2.0 1.00 4.63 83.47 1.82
FHA26104 FHA2610401 0.0 1.0 1.00 11.41 46.86 1.41 1.41 1.0
FHA26105 FHA2610501 0.0 1.0 1.00 15.46 50.97 1.23 1.23 1.0
FHA26106
FHA2610601 0.0 1.0 1.00 23.00 15.05 0.97
0.82 1.5
FHA2610602 1.0 1.5 0.50 40.25 17.24 0.52
FHA26107
FHA2610701 0.0 1.0 1.00 17.67 27.70 5.17
3.38 2.0
FHA2610702 1.0 2.0 1.00 46.72 32.03 1.59
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Figure 1: Auger drilling holes and analytical grades (see legend for grades), with no THM cut-off
used from new results of 57 holes at Fotinho 11000.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Figure 2: Auger drilling holes and analytical grades (see legend for grades), with no THM cut-off
used, from initial 32 holes at Fotinho 11000 and THM results received to date in the Adriano 11002.
Details of Fotinho auger drilling program
Bucket auger (Johnson T-type) drilling within Fotinho 11000 has continued targetting alluvial deposits
adjacent to the numerous rivers and streams within the licence area. THM results from a total of 57
auger holes (refer Tables 1 & 2; Figure 1) and 85 indivudual 1m samples have been received from
MAK Analytical in South Africa (refer Table 2). Individual 1m samples returned analytical grades as
high as 7.69% THM over 1.0m (auger hole FHA26058, refer Table 2). On a drillhole basis, 26 of the
57 target generation holes returned results >3% THM over the entire drilling depth. The results of
holes FHA26044 (4.76% THM over 3.0m) and FHA26046 (4.46% THM over 3.0m) show that some of
the auger holes have high grade to relatively deep depths (refer Table 2). The weighted grade
average for all 32 holes, using no cut off, is an average of 2.95% THM over an average thickness of
1.38m. While some of the holes stopped at the contact with subcrop (rock base to the alluvials),
many of the holes stopped in the watertable, or where the auger drilling could not penetrate coarser
alluvial material.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
The silt and oversize results are highly variable, the %Silt varying from 4.15% to 83.47% and an
average of 26.00%; while the %Oversize varies from 0.42% to 46.72% and an average of 12.13% (refer
Table 2).
Figure 3: Panned HMC from auger holes FHA26072 and FHA26076, with the laboratory results
shown (refer Table 2 for full results).
Cautionary Statement
The auger drilling undertaken at both the Fotinho and Adriano licences are for target generation.
Several holes have not reached the base of the alluvial deposits and additional exploration is needed
for deeper testwork. The current auger drilling will be expanded by grid drilling in target areas, the
current information therefore does not supply any information on the possibly width and strike of
the alluvial deposits.
Non-Executive Director, Chris Gregory, said:
“Each phase of work is adding confidence to the geological model. The new south-east drilling not
only reinforces the strength of the alluvial system, but also aligns with the mapped pegmatite trend
and the historic high-grade stream results. What we are now seeing across Adriano—and increasingly
toward Fotinho—is a coherent, connected mineralised pathway within a shared drainage system. If
assays confirm this linkage, it would represent the foundations of a genuine district-scale rare earth
corridor.”
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
MRG Metals Chairman, Andrew Van Der Zwan, said:
“Our team has moved quickly to build on the strong results delivered last month and we are now
seeing real momentum across the Adriano–Fotinho corridor. With additional drilling completed,
further samples heading to the laboratory and fieldwork expanding into new parts of the licence, we
are steadily advancing our understanding of what may become a district-scale rare earth opportunity.
As assays begin to flow, we remain well-positioned to make informed investment decisions and
continue unlocking value across this emerging asset.”
Competent Persons’ Statement
The information in this report, as it relates to Mozambique Exploration Results, is based on
information compiled and/or reviewed by Mr JN Badenhorst, who is a member of the South African
Council for Natural Scientific Professions (SACNASP) and the Geological Society of South Africa (GSSA).
Mr Badenhorst is a consultant of the Company and has sufficient experience which is relevant to the
style of mineralisation and type of deposits under consideration and to the activity which has been
undertaken to qualify as a Competent Person as defined in the 2012 Edition of the “Australasian Code
for Reporting of Exploration Results, Mineral Resources and Ore Reserves”. Mr Badenhorst consents
to the inclusion in this report of the matters based on the information in the form and context in which
they appear.
This announcement has been authorised for release by the MRG Metals Limited Board of Directors.
For more information please contact:
MRG Metals Investor Relations
Andrew Van Der Zwan Angus Kennelly
Chairman Massive Intelligence
M: +61 (0) 400 982 987 E: angus@massiveintelligence.com.au
E: andrew@mrgmetals.com.au
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Section 1 Sampling Techniques and Data
Criteria Explanation Comment
Sampling techniques Nature and quality of
sampling (eg cut channels,
random chips, or specific
specialised industry
standard measurement
tools appropriate to the
minerals under
investigation, such as down
hole gamma sondes, or
handheld XRF instruments,
etc). These examples
should not be taken as
limiting the broad meaning
of sampling.
Include reference to
measures taken to ensure
sample representivity and
the appropriate calibration
of any measurement tools
or systems used.
Aspects of the
determination of
mineralisation that are
Material to the Public
Report. In cases where
‘industry standard’ work
has been done this would
be relatively simple (eg
‘reverse circulation drilling
was used to obtain 1 m
samples from which 3 kg
was pulverised to produce
a 30 g charge for fire
assay’). In other cases more
explanation may be
• Samples from the hand-auger are collected at
0.5m interval, and composited to 1m intervals.
• Samples of c 2kg are then sent to the analytical
laboratory for analyses.
• At each 0.5m sample a photo is taken showing the
sample bag with hole ID and depth, as well as a
panned sample for the interval.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
required, such as where
there is coarse gold that
has inherent sampling
problems. Unusual
commodities or
mineralisation types (eg
submarine nodules) may
warrant disclosure of
detailed information.
Drilling techniques Drill type (eg core, reverse
circulation, open-hole
hammer, rotary air blast,
auger, Bangka, sonic, etc)
and details (eg core
diameter, triple or standard
tube, depth of diamond
tails, face-sampling bit or
other type, whether core is
oriented and if so, by what
method, etc).
• First pass exploratory hand-auger drilling of
alluvial deposits (57 holes in this release to add to
the already reported 33 holes) were drilled to
define alluvial targets around the various rivers
and streams in Fotinho 11000.
• The hand-auger is a Johnson T-type, 75mm bucket
auger with 1m extension rods and a handle
crossbar.
• The hand-auger samples are from a bucket auger,
thus face-sampling with minimal contamination.
Drill sample recovery Method of recording and
assessing core and chip
sample recoveries and
results assessed.
Measures taken to
maximise sample recovery
and ensure representative
nature of the samples.
Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
• When the bucket auger is re-inserted into the
drillhole after collecting the sample from the
bucket, close attention is given that the depth the
auger goes to is the same depth as per previous
drilling. If not, collapse has happened and the hole
is redrilled, or seen as completed to the collapsed
depth.
• Each 0.5m sample is weighed.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
Logging Whether core and chip
samples have been
geologically and
geotechnically logged to a
level of detail to support
appropriate Mineral
Resource estimation,
mining studies and
metallurgical studies.
Whether logging is
qualitative or quantitative
in nature. Core (or costean,
channel, etc) photography.
The total length and
percentage of the relevant
intersections logged.
• All auger samples are geologically logged, both
the fine and coarse fractions
• The full sample for each intersection is collected,
no sieving of oversize is taking place in the field.
• Analyses at the analytical laboratory is
quantitative as it will supply the exact
information needed for MRE work.
• Photographs were taken of each 0.5m sample
interval, showing the sample bag with hole and
depth ID, as well as a heavy mineral concentrate
(HMC) pan for each interval.
Sub-sampling
techniques and
sample preparation
If core, whether cut or
sawn and whether quarter,
half or all core taken.
If non-core, whether riffled,
tube sampled, rotary split,
etc and whether sampled
wet or dry.
For all sample types, the
nature, quality and
appropriateness of the
sample preparation
technique.
Quality control procedures
adopted for all sub-
sampling stages to
maximise representivity of
samples.
Measures taken to ensure
that the sampling is
representative of the in situ
material collected,
• The full 0.5m sample is collected in a plastic bag.
• Samples are transported to the sampling handling
facility
• 0.5m samples are then combined within each
drillhole into 1m intervals.
• A c 2kg sample were riffle split for laboratory
work, the rest of the sample is stored at the camp
area.
• No screening or sieving took place on site.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
including for instance
results for field
duplicate/second-half
sampling.
Whether sample sizes are
appropriate to the grain
size of the material being
sampled.
Quality of assay
data and laboratory
tests
The nature, quality and
appropriateness of the
assaying and laboratory
procedures used and
whether the technique is
considered partial or total.
For geophysical tools,
spectrometers, handheld
XRF instruments, etc, the
parameters used in
determining the analysis
including instrument make
and model, reading times,
calibrations factors applied
and their derivation, etc.
Nature of quality control
procedures adopted (eg
standards, blanks,
duplicates, external
laboratory checks) and
whether acceptable levels
of accuracy (ie lack of bias)
and precision have been
established.
• 85 samples from 57 holes were sent to MAK
Analytical in South Africa for analyses.
• Samples are dried; then the % Silt (45µ) and
oversize (>1mm) determined; Followed by
%THM on the -1mm +45µ fraction by
Tetrabromoethane (SG 2.95).
• The field derived visual panned THM
estimates are compared to a range of
laboratory derived THM images of pan
concentrates. This allows the field geologists
to calibrate the field panned visual
estimated THM with known laboratory
measured THM grades.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
Verification of
sampling and
assaying
The verification of
significant intersections by
either independent or
alternative company
personnel.
The use of twinned holes.
Documentation of primary
data, data entry
procedures, data
verification, data storage
(physical and electronic)
protocols.
Discuss any adjustment to
assay data.
• The auger drilling represents early-stage
exploratory drilling.
• Field photographs of every sample is done
showing panned HMC for every sample.
• The Chief Geologist checks the logged data
vs the analytical results for each sample
interval.
• The geologic field data is manually
transcribed into a master Microsoft Excel
spreadsheet which is appropriate for this
stage in the exploration program.
• The raw field data is checked in the
Microsoft Excel format first to identify any
obvious errors or outlier data. The data is
then imported into a Microsoft Access
database where it is subjected to various
validation queries.
• Test work has not yet been undertaken at a
Secondary laboratory to check the veracity
of the Primary laboratory data. This work is
planned as part of the Company’s standard
QA/QC procedure.
• A process of laboratory data validation
using mass balance is undertaken to identify
entry errors or questionable data.
• Field and laboratory duplicate data pairs
(THM/oversize/slime) of each batch are
plotted to identify potential quality control
issues.
Location of data
points
Accuracy and quality of
surveys used to locate drill
holes (collar and down-hole
surveys), trenches, mine
workings and other
locations used in Mineral
Resource estimation.
Specification of the grid
system used.
Quality and adequacy of
topographic control.
• The location data from all sampling in is via
a handheld Garmin GPS. The handheld GPS
has an accuracy of +/-5m in the horizontal,
with this accuracy sufficient for the early
phase target generation work taking place.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
Data spacing and
distribution
Data spacing for reporting
of Exploration Results.
Whether the data spacing
and distribution is sufficient
to establish the degree of
geological and grade
continuity appropriate for
the Mineral Resource and
Ore Reserve estimation
procedure(s) and
classifications applied.
Whether sample
compositing has been
applied.
• The hand-auger drilling is currently on a
wider spacing to determine if mineralisation
is present in the alluvial deposits. Analytical
results have shown high %THM, positive
results from mineralogical investigations
will result in infill drilling to facilitate
geological and grade interpretation and
modelling.
Orientation of data
in relation to
geological structure
Whether the orientation of
sampling achieves
unbiased sampling of
possible structures and the
extent to which this is
known, considering the
deposit type.
If the relationship between
the drilling orientation and
the orientation of key
mineralised structures is
considered to have
introduced a sampling bias,
this should be assessed and
reported if material.
• The alluvial deposits are adjacent to a river system
and are being drilled out to depth of drilling
refusal.
• Where the alluvial deposits are not developed,
drilling will immediately stop in hard-rock areas.
• Current drilling is continuing, with the aim to cover
all river and stream systems with initial auger
drilling, infill drilling will take place on areas with
well-developed alluvial deposits and heavy
mineral mineralisation.
• Grid based drilling will now develop an
understanding of the width, strike and depth of
the generated targets.
Sample security The measures taken to
ensure sample security.
• All samples remain in the custody of Company
representatives on the project areas, as well as
during transport to the sample export facility.
• A reputable commercial shipping company, DHL,
was used to transport the samples directly to the
analytical laboratory.
MRG Metals Limited ABN: 83 148 938 532 / ASX Code: MRQ Phone: +61 3 5330 5800 / Fax: +61 3 5330 5890
12 Anderson Street West, Ballarat VIC 3350 / PO Box 237 Ballarat VIC 3353 www.mrgmetals.com.au / info@mrgmetals.com.au
Criteria Explanation Comment
Audits or reviews The results of any audits or
reviews of sampling
techniques and data.
No review has taken place on data to date.
Section 2 Reporting of Exploration Results
Criteria Explanation Comment
Mineral tenement
and land tenure
status
Type, reference
name/number,
location and ownership
including agreements
or material issues with
third parties such as
joint ventures,
partnerships,
overriding royalties,
native title interests,
historical sites,
wilderness or national
park and
environmental
settings.
The security of the
tenure held at the time
of reporting along with
any known
impediments to
obtaining a licence to
operate in the area.
• Exploration licence Fotinho 11000 (Rare earth
Elements, 19 865.18 ha) was issued on 08/10/2024 and
this first period is valid till 08/01/2029.
Exploration done
by other parties
Acknowledgment and
appraisal of
• Data from a regi
Share your feedback
Discover